Hydraulic Driven Centrifugal Pumps | Max Series
General Advantages
Ace developed the first hydraulic motor driven pump at the request of John Deere in 1969. Many of the original pumps are still operating today after more than 30 years of service.
Centrifugal pump design provides good resistance to abrasive solutions and extra flow for agitation. The advantages of the hydraulic motor driven pump are mounting versatility, customized performance, and ease of maintenance. All hydraulic driven pumps are equipped with a stainless steel shaft and wear ring for excellent corrosion resistance.
- MOUNTING VERSATILITY: The location of the pump is not tied to the PTO or engine drive shaft; the pump can be mounted in a variety of locations to suit application requirements.
- CUSTOMIZED PERFORMANCE: The performance is dependent on the supply of hydraulic oil to the motor and not necessarily tied to engine speed. A hydraulic driven pump can produce higher pressures than PTO or belt driven pumps. They can also hold constant pressure at varying engine speeds on closed center hydraulic systems.
- EASY MAINTENANCE: On a hydraulic driven pump there are no belts to align or break. Separate pump and hydraulic motor shafts simplify repair and replacement. Two main pump bearings support shaft loads. All pumps are equipped with easily replaceable FKM mechanical seals.
The Ace gear type hydraulic motor is more efficient than gerotor type motors, and is less subject to damage by contamination than the gerotor design. A built-in needle valve allows for the bypass of up to 9 GPM excess hydraulic fluid on open center systems. The standard motor has a reverse flow check valve which prevents backward hookup and a coasting check which protects the motor seal from the flywheel effect of the impeller. A restrictor orifice is included with pump models recommended for pressure compensating closed center systems. The Ace Internet Hydraulic Selection Guide is here to help in finding the proper hydraulic pump for your tractor.
FMC-650-HYD


SUCTION | DISCHARGE |
---|---|
1-1/2 NPT | 1-1/4 NPT |

- Modified impeller design develops higher pressure at lower RPM.
- Durable E-Coat finish provides extra corrosion resistance on all surfaces inside and out.
- Oversized bearings for extended pump life.
- Splined motor to pump shaft connection strengthens the power train while allowing for easy repair and maintenance.
- 4000 PSI high efficiency pressure plated gear motor provides higher output with less oil flow.
- The M16 motor requires 14 GPM (53 LPM) maximum hydraulic fluid input. Recommended for:
- Pressure Compensating Closed Center Systems
- Load Sensing Closed Center Systems
- Open Center Systems up to 14 GPM (53 LPM)
FMC-650F-HYD | FMC-650F-HYD-PWM


SUCTION | DISCHARGE |
---|---|
220 Flange | 200 Flange |
1-1/2 NPT | 1-1/4 NPT |

- Modified impeller design develops higher pressure at lower RPM.
- F model equipped with NPT ports and industry standard flanged connections.
- Durable E-Coat finish provides extra corrosion resistance on all surfaces inside and out.
- Oversized bearings for extended pump life.
- Splined motor to pump shaft connection strengthens the power train while allowing for easy repair and maintenance.
- 4000 PSI high efficiency pressure plated gear motor provides higher output with less oil flow.
- Optional motor with integrated PWM (pulse width modulated) motor for precision applications
- The M16 motor requires 14 GPM (53 LPM) maximum hydraulic fluid input. Recommended for:
- Pressure Compensating Closed Center Systems
- Load Sensing Closed Center Systems
- Open Center Systems up to 14 GPM (53 LPM)
FMC-650FS-HYD | FMC-650FS-HYD-PWM


SUCTION | DISCHARGE |
---|---|
220 Flange | 200 Flange |
1-1/2 NPT | 1-1/4 NPT |

- Modified impeller design develops higher pressure at lower RPM.
- F model equipped with NPT ports and industry standard flanged connections.
- Durable E-Coat finish provides extra corrosion resistance on all surfaces inside and out.
- Oversized bearings for extended pump life.
- Splined motor to pump shaft connection strengthens the power train while allowing for easy repair and maintenance.
- 4000 PSI high efficiency pressure plated gear motor provides higher output with less oil flow.
- Optional motor with integrated PWM (pulse width modulated) motor for precision applications
- The M16 motor requires 14 GPM (53 LPM) maximum hydraulic fluid input. Recommended for:
- Pressure Compensating Closed Center Systems
- Load Sensing Closed Center Systems
- Open Center Systems up to 14 GPM (53 LPM)
FMCWS-650F-HYD | FMCWS-650F-HYD-PWM


SUCTION | DISCHARGE |
---|---|
220 Flange | 200 Flange |
1-1/2 NPT | 1-1/4 NPT |

- Modified impeller design develops higher pressure at lower RPM.
- F model equipped with NPT ports and industry standard flanged connections.
- Durable E-Coat finish provides extra corrosion resistance on all surfaces inside and out.
- Oversized bearings for extended pump life.
- Splined motor to pump shaft connection strengthens the power train while allowing for easy repair and maintenance.
- 4000 PSI high efficiency pressure plated gear motor provides higher output with less oil flow.

- Ace Pump’s exclusive Oasis WetSeal Technology
- Optional motor with integrated PWM (pulse width modulated) motor for precision applications
- The M16 motor requires 14 GPM (53 LPM) maximum hydraulic fluid input.
- Recommended for:
- Pressure Compensating Closed Center Systems
- Load Sensing Closed Center Systems
- Open Center Systems up to 14 GPM (53 LPM)
FMCWS-650FS-HYD | FMCWS-650FS-HYD-PWM


SUCTION | DISCHARGE |
---|---|
220 Flange | 200 Flange |
1-1/2 NPT | 1-1/4 NPT |

- Modified impeller design develops higher pressure at lower RPM.
- F model equipped with NPT ports and industry standard flanged connections.
- Durable E-Coat finish provides extra corrosion resistance on all surfaces inside and out.
- Oversized bearings for extended pump life.
- Splined motor to pump shaft connection strengthens the power train while allowing for easy repair and maintenance.
- 4000 PSI high efficiency pressure plated gear motor provides higher output with less oil flow.

- Ace Pump’s exclusive Oasis WetSeal Technology
- Optional motor with integrated PWM (pulse width modulated) motor for precision applications
- The M16 motor requires 14 GPM (53 LPM) maximum hydraulic fluid input. Recommended for:
- Pressure Compensating Closed Center Systems
- Load Sensing Closed Center Systems
- Open Center Systems up to 14 GPM (53 LPM)
FMC-750F-HYD-M22 | FMC-750F-HYD-M25 | FMC-750F-HYD-M22-PWM


SUCTION | DISCHARGE |
---|---|
300 Flange | 220 Flange |

- Pressure balanced impeller eliminates thrust load on bearings.
- Standard industry flanged ports for higher flow.
- Optional M22 motor with integrated PWM (pulse width modulated) motor for precision applications

- The M22 motor requires 18 GPM (65.8 LPM) maximum hydraulic fluid input. Recommended for:
- Pressure Compensating Closed Center Systems
- Load Sensing Closed Center Systems
- Open Center Systems up to 18 GPM (65.8 LPM)
- The M25 motor requires 20 GPM (75.7 LPM) maximum hydraulic fluid input. Recommended for:
- Pressure Compensating Closed Center Systems
- Load Sensing Closed Center Systems
- Open Center Systems up to 20 GPM (75.7 LPM)
FMC-755FS-HYD-M22 | FMC-755FS-HYD-M25 | FMC-755FS-HYD-M22-PWM


SUCTION | DISCHARGE |
---|---|
300 Flange | 220 Flange |

- Maximum Flow = 290 GPM (1098 LPM)
- Maximum Pressure = 150 PSI (10.3 BAR)
- Operates at Lower RPM
- E-Coat Corrosion Protection
- High Efficiency 4000 PSI (275 BAR) Pressure Plated Gear Motor
- Optional M22 motor with integrated PWM (pulse width modulated) motor for precision applications
- Optional Case Drain Available

- The M22 motor requires 18 GPM (65.8 LPM) maximum hydraulic fluid input. Recommended for:
- Pressure Compensating Closed Center Systems
- Load Sensing Closed Center Systems
- Open Center Systems up to 18 GPM (65.8 LPM)
- The M25 motor requires 20 GPM (75.7 LPM) maximum hydraulic fluid input. Recommended for:
- Pressure Compensating Closed Center Systems
- Load Sensing Closed Center Systems
- Open Center Systems up to 20 GPM (75.7 LPM)
FMC-855F-HYD


SUCTION | DISCHARGE |
---|---|
300 Flange | 300 Flange |

- Pressure balanced impeller eliminates thrust load on bearings.
- Standard industry flanged ports for higher flow.

- The M30 motor requires 23 GPM (87 LPM) maximum hydraulic fluid input. Recommended for:
- Pressure Conpensating Closed Center Systems
- Load Sensing Closed Center Systems
- Open Center Systems up to 23 GPM (87 LPM)