Maximum
Shutoff
Pressure:
80 PSI(210)/120 PSI(304)
Important
Information:
Tractors with open center hydraulic systems 16 GPM and larger use the -310 motors only.
Installation
Instruction for OPEN CENTER System
1. Shut
off all flow from ACE pump.
2. Install pressure gauge between pump and shut off valve.
3. Open Bypass Adjusting Screw 3 or 4 turns.
4. Set tractor throttle to speed at which you will be spraying.
5. Turn Bypass Adjusting Screw clockwise until pressure gauge on sprayer
reads between 60 and 100psi. Tighten jam nut.