Make: Versatile
Model: 876
System: LOAD SENSING

ACE PUMP CORPORATION
P.O. Box 13187
1650 Channel Avenue
Memphis, TN 38113
Phone: (901) 948-8514
Fax: (901) 774-6147
Pump Model#
FMC-HYD-210
Port Sizes
1-1/4 X 1
Max Flow:
 100 GPM
Maximum Shutoff
Pressure:
100 PSI
Pump Model#
FMC-150-HYD-206
Port Sizes
1-1/2 X 1-1/4
Max Flow:
 120 GPM
Maximum Shutoff
Pressure:
120 PSI
Pump Model#
FMC-200-HYD-210/304
Port Sizes
2 X 1-1/2
Max Flow:
 200 GPM
Maximum Shutoff
Pressure:
80 PSI(210)/120 PSI(304)



Installation Instruction for LOAD SENSING System

1. Install flow limiter in motor inlet. (suggested)
2. Shut off sprayer boom and agitation valves. Install pressure gauge between pump and shut off valve.
3. Close motor needle valve; loosen jam nut, screw needle valve clockwise until seated, and lock nut.
4. Adjust tractor flow control to minimum flow setting (turtle).
5. Move hydraulic lever to "Lower/Retract position to start pump.
6. Adjust tractor flow control until sprayer shut-off pressure is below maximum shown in table.

If the flow limiter stops oil flow to the motor:

6a) Move hydraulic lever to "Float" or "Neutral" to remove oil pressure from the flow limiter.
6b) Adjust tractor flow control to a lower flow position.
6c) Repeat steps 5 and 6.

7. Open the sprayer agitation valve to get desired spraying pressure.